Bayshire Yorba Linda Post-acute
BAYSHIRE YORBA LINDA POST-ACUTE in YORBA LINDA, CA — inspection on April 7, 2025.
Found 2 citations. Severity: Standard violations.
Health inspections identify deficiencies that facilities must correct within required timeframes. Violations range from minor documentation issues to serious safety concerns and are subject to follow-up verification.
Inspection Findings
Review of the facility's document titled Freezer Door Cleaning Log showed it was signed off on 3/3, 3/10, 3/17, 3/24, and 3/31/25.
b. On 4/1/25 at 0821 hours, during the initial tour of the satellite kitchen, ice build-up was observed inside the freezer.
The Dietary Aide verified the above findings.
c. On 4/1/25 at 1133 hours, an inspection of the refrigerator used for the residents' food brought from outside and concurrent interview was conducted with RN 1. An ice-build up was observed inside the freezer and a brownish discoloration was observed on the shelves of the refrigerator used for the residents' food brought from the outside source. RN 1 verified the above findings.
On 4/3/25 at 0949 hours, an interview was conducted with the Director of Maintenance.
The Director of Maintenance stated the housekeeping staff was responsible for the weekly cleaning of the refrigerator used for the residents' food brought from the outside sources, which was usually on Mondays.
On 4/3/25 at 1016 hours, an interview was conducted with the CDM.
The CDM stated the dietary staff was responsible for the weekly cleaning of the refrigerator used for residents' food brought from outside sources.
4.
According to the FDA Food Code 2022, section 4-502.11, showed food temperature measuring devices shall be calibrated in accordance with manufacturer's specifications as necessary to ensure their accuracy.
Review of the Lonicera Thermometer User Instruction (undated) showed to calibrate, take a cup of water and insert the probe into the ice water to touch the ice.
When the final temperature is reached, hold down the CAL button for five seconds.
After five seconds, the display will flash CAL on the screen, then the digit will flash, then press the C/F button to increase the digit or the HOLD button to decrease the digit until 0C or 32 F is reached.
Review of the facility's P&P titled How to Calibrate Thermometers: Bi-Metallic Stem and Digital revised 12/12/19, showed calibration of thermometers is a must in order to assure the temperature displayed on the thermometer is accurate.
The method of calibration for bi-metallic stem and digital thermometers includes the following:
555768
Form Approved OMB
STATEMENT OF DEFICIENCIES (X1) PROVIDER/SUPPLIER/CLIA (X2) MULTIPLE CONSTRUCTION (X3) DATE SURVEY AND PLAN OF CORRECTION IDENTIFICATION NUMBER: COMPLETED A.
Building 555768 B.
Wing 04/07/2025
NAME OF PROVIDER OR SUPPLIER STREET ADDRESS, CITY, STATE, ZIP CODE
Bayshire Yorba Linda Post-Acute 17803 Imperial Highway Yorba Linda, CA 92886
According to the 2022 FDA Food Code, ,d+[DATE].11, Equipment and Utensils, Air- Drying Required, showed items must be allowed to drain and to air-dry before being stacked or stored.
Stacking wet items such as pans prevents them from drying and may allow an environment where microorganism can begin to grow.
Cloth drying of equipment and utensils is prohibited to prevent the possible transfer of microorganisms.
555768
Form Approved OMB
STATEMENT OF DEFICIENCIES (X1) PROVIDER/SUPPLIER/CLIA (X2) MULTIPLE CONSTRUCTION (X3) DATE SURVEY AND PLAN OF CORRECTION IDENTIFICATION NUMBER: COMPLETED A.
Building 555768 B.
Wing 04/07/2025
NAME OF PROVIDER OR SUPPLIER STREET ADDRESS, CITY, STATE, ZIP CODE
Bayshire Yorba Linda Post-Acute 17803 Imperial Highway Yorba Linda, CA 92886