The resident, identified in inspection records as Resident 31, had the midline catheter placed on February 4, 2025, by an outside company. Documentation from that insertion showed the line going into the resident's right upper arm. She was receiving Vancomycin, an intravenous antibiotic used for serious infections, twice daily for a urinary tract infection, with treatment running through February 11.
A midline catheter is not a standard peripheral IV. It is longer, threading further into the vein, and it creates a direct pathway for pathogens to enter the body. The CDC classifies midlines as indwelling medical devices and, unlike ordinary peripheral IVs, requires Enhanced Barrier Precautions when one is in place. Those precautions, known as EBP, require staff to wear gowns and gloves when providing care to a resident, reducing the risk that bacteria carried on clothing or hands travel into the line and into the bloodstream.
Lions Gate had a written policy on exactly this. Reviewed as recently as December 2024, it listed midlines alongside PICC lines and central lines as devices that trigger the EBP requirement. The policy was not new. The guidance was not ambiguous.
None of it reached Resident 31.
When a surveyor interviewed the facility's Infection Preventionist on February 11, 2025, the IP said that yes, a resident with a midline catheter should be on Enhanced Barrier Precautions. Then she explained why Resident 31 was not: she had believed the resident had a peripheral IV site, not a midline. She had not looked closely enough, or asked, or checked the insertion documentation sitting in the record.
The Director of Nursing, interviewed the following day, confirmed what everyone already knew. A midline requires EBP. It had not been implemented.
The physician order to remove the midline was dated February 11, the same day the surveyor started asking questions. By the time inspectors documented the lapse, the line was already coming out.
CMS rated the harm level as minimal, with potential for actual harm, and noted that some residents were affected. The deficiency fell under New Jersey's long-term care regulations governing infection control practices.
What the inspection doesn't answer is how long the gap might have persisted if no one had come to ask. The midline was placed February 4. The surveyor's interview was February 11. That is seven days during which a resident received IV antibiotics through a catheter that staff were supposed to be treating with heightened precautions, and weren't, because the person responsible for tracking exactly these situations had the wrong picture in her head.
Infection preventionists in nursing homes exist because the consequences of getting this wrong are severe. A line infection in a frail elderly resident can move fast. Vancomycin is itself a last-resort antibiotic, deployed when other drugs have failed or when the organism is resistant. The residents who receive it are not the ones with uncomplicated infections.
The facility's own paperwork had the answer. The insertion form from February 4 described a midline placed in the right upper arm. The December 2024 policy named midlines as devices requiring gowns and gloves. The IP knew the rule. She just didn't know which category her patient fell into.
Resident 31 completed her course of antibiotics and had the line removed. Whether she developed any complications from the unprotected week is not recorded in the inspection report.
Full Inspection Report
The details above represent a summary of key findings. View the complete inspection report for Lions Gate from 2025-02-13 including all violations, facility responses, and corrective action plans.
Additional Resources
Data source: This article is based on inspection data downloaded directly from the Centers for Medicare & Medicaid Services (CMS) via Medicare.gov. CMS releases inspection reports in bulk; we publish the findings as documented by state surveyors in the official Form CMS-2567 Statement of Deficiencies.
Plan of correction: The CMS report we receive does not include the facility's plan of correction. Facilities submit plans of correction separately to state survey agencies and those responses may not be reflected in CMS data at the time of publication. The absence of a plan of correction in our data does not mean one was not filed. Readers who want information about corrective steps taken are encouraged to contact the facility directly or their state survey agency.
Corrections may have occurred: Inspection reports reflect conditions observed on the date of the survey. Facilities may have implemented corrections, staffing changes, additional training, or other remediation since the report was issued. We report what CMS provides and encourage readers to seek current information from the facility.
Editorial process: Inspection findings are extracted from CMS source documents and synthesized using AI, reviewed for factual accuracy against the original report by our editorial team.
Corrections: We strive for accuracy in everything we publish. If you believe any fact in this article is incorrect, please contact us with details, and we will review and correct it promptly.
Professional review: All content reviewed by Christopher F. Nesbitt, Sr., NH EMT & BU-trained Paralegal.
Last verified: November 19, 2026 · Our methodology
LIONS GATE in VOORHEES, NJ was cited for violations during a health inspection on February 13, 2025.
The resident, identified in inspection records as Resident 31, had the midline catheter placed on February 4, 2025, by an outside company.