Aspen Hill Rehab: PICC Line Dressing Left Unchanged - MA
The resident, identified in inspection records only as Resident #106, was admitted to the facility in November 2024. His diagnoses included metabolic encephalopathy, falls, anxiety, and atrial fibrillation. He had moderate cognitive impairment. He needed help with daily activities. And starting in early January 2025, he was receiving intravenous Daptomycin, an antibiotic, once a day through a PICC line to treat bacteremia, an infection in the bloodstream. The treatment was ordered to run through January 18.
His physician's orders were clear: change the transparent dressing on the PICC line every seven days. Check the external length of the catheter with each dressing change. Monitor the insertion site daily.
When a state surveyor examined Resident #106's PICC line on the morning of January 14, the dressing bore a date of January 2. Twelve days. No change.
The Medication Administration Record told a different story. According to that record, Nurse #3 had changed the transparent dressing on January 10, four days earlier, right on schedule.
She hadn't.
During an interview the following morning, Nurse #3 told the surveyor she had never changed a PICC line dressing. She said she didn't know how. She believed only Registered Nurses were permitted to perform the task, and she was a Licensed Practical Nurse. Then she said something that captures the problem precisely: when orders are signed off on the Treatment Administration Record, she said, they should be completed.
She signed off. The order was not completed.
The Unit Manager, also interviewed on January 15, confirmed she had seen the PICC line herself on January 14 and noted the date still read January 2. She acknowledged the dressing should have been changed every seven days, and that the required measurements had not been obtained.
The Director of Nursing, interviewed that same afternoon, confirmed PICC line dressings need to be changed every seven days. She said nurses completing dressing changes should also obtain the required measurements of the catheter's external length, a check that helps detect whether the line has shifted position.
None of that had happened.
A PICC line, a peripherally inserted central catheter, runs from a vein in the upper arm to a large vein near the heart. It is used precisely because it provides reliable access for medications that need to reach the bloodstream quickly and consistently, like the antibiotic Resident #106 was receiving for his blood infection. The dressing covering the insertion site is not incidental. It is the barrier between the catheter entry point and the outside world. When it goes unchanged, the site becomes a potential entry point for new infection in a patient already fighting one.
Resident #106 had moderate cognitive impairment. He could not have been expected to notice the date on his own dressing, or to know that the nurse who signed off on his care had recorded a procedure she never performed.
The inspection was conducted January 16, 2025. Inspectors cited the deficiency at a level of minimal harm or potential for actual harm, affecting few residents.
What the record does not show is who, if anyone, eventually changed the dressing, or whether the line had shifted from its original position in the days it went unmeasured. The physician's order requiring the antibiotic ran through January 18. Whether Resident #106 received his full course of treatment through a properly maintained line is not something the inspection report addresses.
His care plan said to monitor the insertion site daily and change the dressing as ordered. For at least twelve days, neither happened. And the record said otherwise.
Full Inspection Report
The details above represent a summary of key findings. View the complete inspection report for Aspen Hill Rehabiliation & Healthcare Center from 2025-01-16 including all violations, facility responses, and corrective action plans.
Additional Resources
Data source: This article is based on inspection data downloaded directly from the Centers for Medicare & Medicaid Services (CMS) via Medicare.gov. CMS releases inspection reports in bulk; we publish the findings as documented by state surveyors in the official Form CMS-2567 Statement of Deficiencies.
Plan of correction: The CMS report we receive does not include the facility's plan of correction. Facilities submit plans of correction separately to state survey agencies and those responses may not be reflected in CMS data at the time of publication. The absence of a plan of correction in our data does not mean one was not filed. Readers who want information about corrective steps taken are encouraged to contact the facility directly or their state survey agency.
Corrections may have occurred: Inspection reports reflect conditions observed on the date of the survey. Facilities may have implemented corrections, staffing changes, additional training, or other remediation since the report was issued. We report what CMS provides and encourage readers to seek current information from the facility.
Editorial process: Inspection findings are extracted from CMS source documents and synthesized using AI, reviewed for factual accuracy against the original report by our editorial team.
Corrections: We strive for accuracy in everything we publish. If you believe any fact in this article is incorrect, please contact us with details, and we will review and correct it promptly.
Professional review: All content reviewed by Christopher F. Nesbitt, Sr., NH EMT & BU-trained Paralegal.
Last verified: November 21, 2026 · Our methodology
ASPEN HILL REHABILIATION & HEALTHCARE CENTER in HAVERHILL, MA was cited for violations during a health inspection on January 16, 2025.
The resident, identified in inspection records only as Resident #106, was admitted to the facility in November 2024.
Health inspections identify deficiencies that facilities must correct. Violations range from minor documentation issues to serious safety concerns. Review the full report below for specific details and facility response.
