Highline Post Acute: Medication Storage Failures - CO
That was one of several medication storage problems inspectors documented during an August 2024 visit to the facility at 6060 East Iliff Avenue. The findings were minor in their rated harm level, but the details told a story about basic storage practices that had gone unmonitored long enough to become routine.
The unlabeled insulin vial was found on the Cherry Creek long hall medication cart. A licensed practical nurse told inspectors that every vial should carry the resident's name, because each resident is supposed to have their own dedicated vial or pen. The director of nursing said the same thing when interviewed and agreed to pull the vial from the cart immediately. By the following afternoon, the facility had obtained a replacement vial, this one properly labeled.
On the Capitol Hill unit, inspectors found a different problem. A vial of Lantus insulin was sitting in the medication cart directly next to Latanoprost eye drops. The registered nurse working the cart that day said medications should be stored according to how they are administered, specifically to prevent infections. Insulin goes under the skin. Eye drops go in the eye. Storing them together creates a contamination risk if a nurse reaches for one and grabs the other.
The medication storage room on the Capitol Hill unit had more problems waiting inside the refrigerator. Inspectors found four 237-milliliter cartons of Boost, a nutritional supplement drink, sharing shelf space with Lorazepam, a controlled antianxiety medication, liquid cephalexin, an antibiotic, and two boxes of Trulicity injectable pens used for glucose control. The registered nurse said food and oral supplements have no place in a medication refrigerator and acknowledged the mixing could cause contamination.
The refrigerator itself was also a problem. It was a dormitory-style unit, the kind with a small freezer compartment built into the interior of the main compartment rather than separated above or below. Ice had built up around and inside that freezer compartment. The registered nurse said ice buildup like that can cause temperature fluctuations, and that medications require storage within a specific temperature range to remain effective.
When the director of nursing was told about the dormitory-style refrigerator, she said those units should not be used for medication storage precisely because their temperatures can fluctuate and compromise what is stored inside. Then she said she had not known the facility had any dormitory-style refrigerators.
That last detail is worth sitting with. The refrigerator was in the medication storage room of an active nursing unit. It had ice visibly built up inside it. It contained controlled substances, antibiotics, and injectable diabetes medication. The director of nursing, who oversees medication management across the facility, did not know it existed.
Inspectors rated the violations at the lowest level of harm, meaning the problems had caused minimal harm or had the potential for actual harm rather than documented injury to residents. A small number of residents were affected. But the gap between what staff knew they were supposed to do and what was actually happening on the unit was consistent across every interview. The nurse knew insulin and eye drops should not share a drawer. The nurse knew food does not belong in the medication refrigerator. The director knew dormitory refrigerators were unsuitable for medications. None of that knowledge had translated into someone checking.
The facility told inspectors it would replace the glargine insulin vial, which it did. What it would do about a medication refrigerator that its own nursing director did not know existed, and that had been icing over long enough to accumulate visible buildup, was not detailed in the inspection record.
Full Inspection Report
The details above represent a summary of key findings. View the complete inspection report for Highline Post Acute from 2024-08-15 including all violations, facility responses, and corrective action plans.
Additional Resources
Data source: This article is based on inspection data downloaded directly from the Centers for Medicare & Medicaid Services (CMS) via Medicare.gov. CMS releases inspection reports in bulk; we publish the findings as documented by state surveyors in the official Form CMS-2567 Statement of Deficiencies.
Plan of correction: The CMS report we receive does not include the facility's plan of correction. Facilities submit plans of correction separately to state survey agencies and those responses may not be reflected in CMS data at the time of publication. The absence of a plan of correction in our data does not mean one was not filed. Readers who want information about corrective steps taken are encouraged to contact the facility directly or their state survey agency.
Corrections may have occurred: Inspection reports reflect conditions observed on the date of the survey. Facilities may have implemented corrections, staffing changes, additional training, or other remediation since the report was issued. We report what CMS provides and encourage readers to seek current information from the facility.
Editorial process: Inspection findings are extracted from CMS source documents and synthesized using AI, reviewed for factual accuracy against the original report by our editorial team.
Corrections: We strive for accuracy in everything we publish. If you believe any fact in this article is incorrect, please contact us with details, and we will review and correct it promptly.
Professional review: All content reviewed by Christopher F. Nesbitt, Sr., NH EMT & BU-trained Paralegal.
Last verified: November 22, 2026 · Our methodology
HIGHLINE POST ACUTE in DENVER, CO was cited for violations during a health inspection on August 15, 2024.
That was one of several medication storage problems inspectors documented during an August 2024 visit to the facility at 6060 East Iliff Avenue.
Health inspections identify deficiencies that facilities must correct. Violations range from minor documentation issues to serious safety concerns. Review the full report below for specific details and facility response.