Skip to main content

Bartow Center: Catheter Care Hygiene Failures - FL

Bartow Center: Catheter Care Hygiene Failures - FL
Healthcare Facility
Bartow Center
Bartow, FL  ·  2/5 stars

The violation centered on perineal and catheter care, the routine but consequential process of cleaning residents who have urinary catheters. Done correctly, the procedure prevents bacteria from being carried from contaminated areas into clean ones. Done incorrectly, it can introduce infection into the urinary tract of a person who already has a tube running directly into their bladder.

What inspectors documented was a failure at one of the most basic steps in the sequence. Staff were not changing their gloves and washing their hands between washing soiled areas and rinsing clean ones. The facility's own competency training document, titled "Competency: Perineal Care/Catheter Care," listed that step explicitly. It was not a matter of interpretation.

The registered nurse and unit manager who spoke with inspectors confirmed what the standard was. Catheter bags, she said, should be stored below the level of the bladder and should not be touching the floor. The assistant director of nursing went further, saying she would expect nursing staff to change gloves and perform hand hygiene between the dirty and clean portions of the procedure, and confirmed that staff are taught exactly that during competency training.

That training document, when inspectors reviewed it, backed her up. Under the section for female residents, the steps were laid out in sequence: apply a small amount of liquid soap to each washcloth as it is being used, clean in a downward motion from front to back, then change water and repeat the procedure to remove soap, change gloves, wash hands, and re-glove before continuing.

The gap between what the document required and what staff were actually doing was not a gray area. Management described the correct procedure accurately. The written competency matched. The practice on the floor did not.

CMS rated the violation at the lower end of the harm scale, classifying it as minimal harm or potential for actual harm, and noted that few residents were affected. That classification reflects the regulatory framework inspectors use, not a judgment that the lapse was inconsequential. Catheter-associated urinary tract infections are among the most common healthcare-acquired infections in long-term care settings. They can cause sepsis. In elderly residents with compromised immune systems, they can be fatal.

The residents at Bartow Center who required catheter care during the period inspectors observed were not identified by name in the report. What the report does establish is that the staff responsible for their care were skipping a step that their own employer had trained them to perform, a step that exists specifically to prevent contamination from moving in the wrong direction across a vulnerable resident's body.

The facility is located at 2055 East Georgia Street in Bartow, a city of roughly 20,000 in Polk County. The inspection was completed July 30, 2024, and the statement of deficiencies was printed the following August.

For the residents who depend on catheter care at Bartow Center, the question the inspection report leaves open is not whether the procedure was being done wrong. Inspectors established that it was. The question is how long it had been done that way before anyone checked, and whether the staff who performed it incorrectly understood, in the moment, what they were risking.

The facility's written training said they did. The unit manager and the assistant director of nursing said they did. What happened in the rooms where the care was actually delivered told a different story.

Full Inspection Report

The details above represent a summary of key findings. View the complete inspection report for Bartow Center from 2024-07-30 including all violations, facility responses, and corrective action plans.

Additional Resources

Editorial Standards & Data Disclosure

Data source: This article is based on inspection data downloaded directly from the Centers for Medicare & Medicaid Services (CMS) via Medicare.gov. CMS releases inspection reports in bulk; we publish the findings as documented by state surveyors in the official Form CMS-2567 Statement of Deficiencies.

Plan of correction: The CMS report we receive does not include the facility's plan of correction. Facilities submit plans of correction separately to state survey agencies and those responses may not be reflected in CMS data at the time of publication. The absence of a plan of correction in our data does not mean one was not filed. Readers who want information about corrective steps taken are encouraged to contact the facility directly or their state survey agency.

Corrections may have occurred: Inspection reports reflect conditions observed on the date of the survey. Facilities may have implemented corrections, staffing changes, additional training, or other remediation since the report was issued. We report what CMS provides and encourage readers to seek current information from the facility.

Editorial process: Inspection findings are extracted from CMS source documents and synthesized using AI, reviewed for factual accuracy against the original report by our editorial team.

Corrections: We strive for accuracy in everything we publish. If you believe any fact in this article is incorrect, please contact us with details, and we will review and correct it promptly.

Professional review: All content reviewed by Christopher F. Nesbitt, Sr., NH EMT & BU-trained Paralegal.

Last verified: November 22, 2026  ·  Our methodology

Quick Answer

BARTOW CENTER in BARTOW, FL was cited for violations during a health inspection on July 30, 2024.

The violation centered on perineal and catheter care, the routine but consequential process of cleaning residents who have urinary catheters.

Health inspections identify deficiencies that facilities must correct. Violations range from minor documentation issues to serious safety concerns. Review the full report below for specific details and facility response.

Frequently Asked Questions

What happened at BARTOW CENTER?
The violation centered on perineal and catheter care, the routine but consequential process of cleaning residents who have urinary catheters.
How serious are these violations?
Violation severity varies from minor documentation issues to serious safety concerns. Review the inspection report for specific deficiency codes and scope. All violations must be corrected within required timeframes and are subject to follow-up verification inspections.
What should families do?
Families should: (1) Ask facility administration about specific corrective actions taken, (2) Request to see the follow-up inspection report verifying corrections, (3) Check if this represents a pattern by reviewing prior inspection reports, (4) Compare this facility's ratings with other nursing homes in BARTOW, FL, (5) Report any new concerns directly to state authorities.
Where can I see the full inspection report?
The complete inspection report is available on Medicare.gov's Care Compare website (www.medicare.gov/care-compare). You can also request a copy directly from BARTOW CENTER or from the state Department of Health. The report includes specific deficiency codes, facility responses, and correction timelines. This facility's federal provider number is 105286.
Has this facility had violations before?
To check BARTOW CENTER's history, visit Medicare.gov's Care Compare and review their inspection history, quality ratings, and staffing levels. Look for patterns of repeated violations, especially in critical areas like abuse prevention, medication management, infection control, and resident safety.

Facility Details
Name Bartow Center
Location Bartow, FL
CMS Rating 2 / 5
Beds 120

Advertisement

Ergonomic memory foam pillow

Losing sleep over a loved one's care?

The Derila Ergo memory foam pillow supports your neck in any sleep position. 60-day return policy.

See the Derila Pillow