The resident, identified in inspection records as Resident 5, had been prescribed two Depakote tablets to be taken together every morning: a 125 mg tablet and a 500 mg tablet, combining for a total dose of 625 mg. The order had been in place since September 2022. When the facility migrated to a new electronic records system on June 11, 2024, the 500 mg portion of that order was entered with a start date of June 30, nineteen days later. For those nineteen days, the medication administration record showed the 500 mg dose was not due to be given.
The error surfaced on June 18, when a federal surveyor asked a unit manager and licensed practical nurse, identified as UM/LPN 2, about the 9 AM Depakote dose for Resident 5. The nurse checked both the old and new electronic systems before confirming the total dose should be 625 mg. Then she found the problem: the 500 mg order had been entered with the wrong start date and would not appear as due for administration until June 30.
UM/LPN 2 could not say how the order had been entered incorrectly.
The June medication administration record showed all dates in June marked with an X, the notation used to record that a medication was given, up through June 30. That meant the 500 mg dose had not been administered on any of those days, while the MAR simultaneously suggested the 125 mg dose had been given throughout the month. The resident had been receiving less than a fifth of their prescribed Depakote for weeks.
The director of nursing acknowledged the error on June 20, two days after the surveyor raised it. She confirmed the facility had switched computer systems on June 11 and that all physician orders had been transferred to the new platform. She said she was still investigating how the entry mistake occurred. She also acknowledged that no medication administration observations had been conducted on the registered nurse responsible for administering medications, and that no recent medication administration training had been completed by staff.
Depakote, the brand name for valproate, is used to treat bipolar disorder and certain seizure conditions. Dosing is calibrated to maintain stable levels in the bloodstream. A gap in the prescribed dose over nearly three weeks carries real clinical consequences for a patient whose treatment depends on that consistency.
The facility's own medication administration policy, dated December 2023, instructs staff to verify that each medication is the right drug, at the right dose, by the right route, at the right time, for the right patient, and to confirm that the medication administration record reflects the most current physician order. The inspection found the facility was not following that policy.
What the record makes clear is that the system migration created a gap nobody caught. The physician's orders from the old system showed the 500 mg and 125 mg doses together, both entered September 2022, both to be given twice daily for a combined 625 mg. The new system broke that link. The 125 mg order carried over correctly. The 500 mg order did not.
For nineteen days, whoever administered the morning medication to Resident 5 gave one tablet instead of two. The MAR did not flag a problem. No one reviewed the transfer against the original orders closely enough to notice. The surveyor found it by asking a single question about one resident's 9 AM dose.
The director of nursing was still investigating when the inspection closed.
Full Inspection Report
The details above represent a summary of key findings. View the complete inspection report for Belle Care Nursing and Rehabilitation Center from 2024-06-26 including all violations, facility responses, and corrective action plans.
Additional Resources
Data source: This article is based on inspection data downloaded directly from the Centers for Medicare & Medicaid Services (CMS) via Medicare.gov. CMS releases inspection reports in bulk; we publish the findings as documented by state surveyors in the official Form CMS-2567 Statement of Deficiencies.
Plan of correction: The CMS report we receive does not include the facility's plan of correction. Facilities submit plans of correction separately to state survey agencies and those responses may not be reflected in CMS data at the time of publication. The absence of a plan of correction in our data does not mean one was not filed. Readers who want information about corrective steps taken are encouraged to contact the facility directly or their state survey agency.
Corrections may have occurred: Inspection reports reflect conditions observed on the date of the survey. Facilities may have implemented corrections, staffing changes, additional training, or other remediation since the report was issued. We report what CMS provides and encourage readers to seek current information from the facility.
Editorial process: Inspection findings are extracted from CMS source documents and synthesized using AI, reviewed for factual accuracy against the original report by our editorial team.
Corrections: We strive for accuracy in everything we publish. If you believe any fact in this article is incorrect, please contact us with details, and we will review and correct it promptly.
Professional review: All content reviewed by Christopher F. Nesbitt, Sr., NH EMT & BU-trained Paralegal.
Last verified: November 26, 2026 · Our methodology
BELLE CARE NURSING AND REHABILITATION CENTER in TRENTON, NJ was cited for violations during a health inspection on June 26, 2024.
The order had been in place since September 2022.